OID reference

eventConfigAction

1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Description

<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE—See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>E…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.6.4.2.1 (eventLogConfigEntry)
Node code
8
Node name
eventConfigAction
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.6.4.2.1.8
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.6.4.2.1.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 6 4 2 1 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigAction(8)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/6/4/2/1/8
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/6/4/2/1/8
  • /ISO/3/6/1/4/1/1206/4/2/6/4/2/1/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigAction
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigAction
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory, deprecated, optional
Default value
disabled

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
disabled

Variant 2 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
deprecated
Default value
disabled

Variant 3 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1other1, 2, 3
2disabled1, 2, 3
3log1, 2, 3

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1201-2004, the row index eventConfigID is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.6.4.2.1.8.<eventConfigID>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 8 distinct definitions; some records may not include a definition.

Show 8 published definitions

eventConfigAction · mandatory

eventConfigAction OBJECT-TYPE
SYNTAX        INTEGER { other (1),
                        disabled (2),
                        log (3)
                        }
ACCESS        read-write
STATUS        mandatory
DESCRIPTION
       "<Definition>The value of this object indicates what action shall
       take place when this event occurs.
       disabled - no entry will be recorded due to this event.
       log - an entry will be recorded in the event log table when this event
       occurs.

       NOTE—See NTCIP 1103 for additional requirements related to traps.


       <DescriptiveName>EventType.action:code
      <DataConceptType>Data Element"
DEFVAL      {disabled}
::= { eventLogConfigEntry 8 }

eventConfigAction · deprecated

eventConfigAction OBJECT-TYPE
SYNTAX       INTEGER { other (1),
                         disabled (2),
                         log (3) }
MAX-ACCESS read-write
STATUS       deprecated
DESCRIPTION
   "<Definition>The value of this object indicates what action shall take
   place when this event occurs.
  <Format>
  Other - indicates that the action is other than defined in this standard.
  This value exists in order to support proprietary event logging mechanisms
  configured by other means not specified in this standard. If this value is
  used in a SET request, the agent shall respond with a badValueError.
  Disabled - no event log entry shall be generated or recorded due to this
  event. In an agent complying with NTCIP 1103 v03 or later, this event shall
  not be used to trigger NTCIP traps, nor to construct NTCIP trap messages.
  Log - an event log entry shall be generated when this event occurs. In an
  agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP
  trap (see the eventConfigID index element of trapTable). If
  eventConfigClass refers to an eventClassTable row having eventClassLimit =
  0, the log entry's eventLogValue shall be used to construct any necessary
  trap messages implied by the associated trapTable rows, but the log entry
  shall then be discarded and not added to the eventLogTable. If the
  eventClassLimit is greater than zero, the log entry shall be added to the
  eventLogTable, subject to the constraints imposed by the associated
  eventConfigClass.




                                                                                    

                                                                                       
                                                                                      

  <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerActionOwner,
  fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO
  26048-1)
  <Informative> The replacement object points to a table that can point to
  multiple actions. For example, a single trigger can result in both a log
  entry and a notification.
  <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
DEFVAL     { disabled }
::= { eventLogConfigEntry 8 }

eventConfigAction · mandatory

eventConfigAction  OBJECT-TYPE
SYNTAX	INTEGER { 
	other (1),
	disabled (2),
	log (3)
	}
ACCESS	read-write
STATUS	mandatory
DESCRIPTION
"<Definition>The value of this object indicates what action shall take place when this event occurs.  
disabled  - no entry will be recorded due to this event.
log - an entry will be recorded in the event log table when this event occurs.

NOTE-See NTCIP 1103 for additional requirements related to traps.  
 
<DescriptiveName>EventType.action:code
<DataConceptType>Data Element"
DEFVAL	{disabled}
::= { eventLogConfigEntry 8 }

eventConfigAction · mandatory

eventConfigAction OBJECT-TYPE
  SYNTAX INTEGER { other (1),
                    disabled (2),
                    log (3) }
   ACCESS read-write
   STATUS mandatory
   DESCRIPTION
      "<Definition>The value of this object indicates what action
        shall take place when this event occurs.
        other    - indicates that the action is other than defined in this
                   standard. This value exists in order to support proprietary
                   event logging mechanisms configured by other means not
                   specified in this standard. If this value is used in a SET
                   request, the agent shall respond with a badValueError.
        disabled - no event log entry shall be generated or recorded due to this
                   event. In an agent complying with NTCIP 1103 v03 or later,
                   this event shall not be used to trigger NTCIP traps, nor to
                   construct NTCIP trap messages.
        log      - an event log entry shall be generated when this event occurs.
                   In an agent complying with NTCIP 1103 v03 and later, this may
                   trigger an NTCIP trap (see the eventConfigID index element of
                   trapTable). If eventConfigClass refers to an eventClassTable
                   row having eventClassLimit = 0, the log entry’s eventLogValue
                   shall be used to construct any necessary trap messages
                   implied by the associated trapTable rows, but the log entry
                   shall then be discarded and not added to the eventLogTable.
                   If the eventClassLimit is greater than zero, the log entry



                                                                                            

                                                                                         
                                                                                        

                       shall be added to the eventLogTable, subject to the
                       constraints imposed by the associated eventConfigClass.

        <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8
      "
   DEFVAL {disabled}
::= { eventLogConfigEntry 8 }

eventConfigAction · mandatory

eventConfigAction OBJECT-TYPE
SYNTAX         INTEGER { other (1),
                            disabled (2),
                            log (3)
                            }
ACCESS         read-write
STATUS         mandatory
DESCRIPTION
      "<Definition>The value of this object indicates what action shall take place when this
      event occurs.
      disabled - no entry will be recorded due to this event.
      log - an entry will be recorded in the event log table when this event occurs.

                              <DescriptiveName>EventType.action:code
         <DataConceptType>Data Element"
DEFVAL          {disabled}
::= { eventLogConfigEntry 8 }

eventConfigAction · deprecated

eventConfigAction  OBJECT-TYPE
  SYNTAX      INTEGER { other (1),
                        disabled (2),
                        log (3) }
  MAX-ACCESS  read-write
  STATUS      deprecated
  DESCRIPTION
    "<Definition>The value of this object indicates what action 
      shall take place when this event occurs.
    <Format>
    Other - indicates that the action is other than defined in this 
      standard. This value exists in order to support proprietary event 
      logging mechanisms configured by other means not specified in this 
      standard. If this value is used in a SET request, the agent shall 
      respond with a badValueError.
    Disabled - no event log entry shall be generated or recorded due to this 
      event. In an agent complying with NTCIP 1103 v03 or later, this event 
      shall not be used to trigger NTCIP traps, nor to construct NTCIP trap 
      messages.
    Log - an event log entry shall be generated when this event occurs. In an 
      agent complying with NTCIP 1103 v03 and later, this may trigger an 
      NTCIP trap (see the eventConfigID index element of trapTable). If 
      eventConfigClass refers to an eventClassTable row having 
      eventClassLimit = 0, the log entry's eventLogValue shall be used to 
      construct any necessary trap messages implied by the associated 
      trapTable rows, but the log entry shall then be discarded and not added 
      to the eventLogTable. If the eventClassLimit is greater than zero, the 
      log entry shall be added to the eventLogTable, subject to the 
      constraints imposed by the associated eventConfigClass.

    <Superseded by> COND-TRIGGER-MIB.fdCondTriggerActionOwner, 
      fdCondTriggerAction, fdCondTriggerActionOwner2, & 
      fdCondTriggerAction2 (ISO 20684-3)
    <Informative> The replacement object points to a table that can point 
      to multiple actions. For example, a single trigger can result in both
      a log entry and a notification.
    <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
   DEFVAL  {disabled}
::= { eventLogConfigEntry 8 }

eventConfigAction · optional

eventConfigAction OBJECT-TYPE
SYNTAX            INTEGER { other (1),
                               disabled (2),
                               log (3) }
ACCESS            read-write
STATUS            optional
DESCRIPTION
"This value of this object indicates the action that will take place when the event described in this row of
the event configuration table occurs.
     disabled - no entry will be recorded due to this event.
     log - an entry will be recorded in the event log table when this event occurs."
::= { eventLogConfigEntry 8 }

eventConfigAction · mandatory

eventConfigAction OBJECT-TYPE
  SYNTAX INTEGER { other (1),
                        disabled (2),
                        log (3) }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "<Definition>The value of this object indicates what action
          shall take place when this event occurs.
          other     - indicates that the action is other than defined
                       in this standard.
          disabled - no entry will be recorded due to this event.
          log       - an entry will be recorded in the event log table
                       when this event occurs.

       <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8
      "
   DEFVAL {disabled}
::= { eventLogConfigEntry 8 }

Meaning

Descriptions

8 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE—See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 26048-1) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE-See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 4

<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry’s eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 5

<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <DescriptiveName>EventType.action:code <DataConceptType>Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 6

<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Superseded by> COND-TRIGGER-MIB.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 20684-3) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 7

This value of this object indicates the action that will take place when the event described in this row of the event configuration table occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 8

<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

8 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

eventConfigAction · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE—See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE—See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

eventConfigAction · deprecatedNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: deprecated.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 26048-1) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 26048-1) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
Records for description 3ITE public NTCIP working repository MIBs1 record · 1 source

Description 3

eventConfigAction · mandatoryITE public NTCIP working repository MIBs1 source

Status in source: mandatory.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE-See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. NOTE-See NTCIP 1103 for additional requirements related to traps. <DescriptiveName>EventType.action:code <DataConceptType>Data Element"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1201 — NTCIP1201-Glo.mib

    Module: NTCIP1201-2004

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Opaque', 'Counter', 'Gauge', 'null'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004-A-2004': ['devices', 'protocols', 'profiles', 'global']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004-A-2004, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP-1201 — NTCIP1201-Glo.mib
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

eventConfigAction · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry’s eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8 \"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry’s eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
Records for description 5NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 5

eventConfigAction · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <DescriptiveName>EventType.action:code <DataConceptType>Data Element\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <DescriptiveName>EventType.action:code <DataConceptType>Data Element"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
Records for description 6ITE public NTCIP working repository MIBs1 record · 1 source

Description 6

eventConfigAction · deprecatedITE public NTCIP working repository MIBs1 source

Status in source: deprecated.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Superseded by> COND-TRIGGER-MIB.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 20684-3) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8\"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. <Format> Other - indicates that the action is other than defined in this standard. This value exists in order to support proprietary event logging mechanisms configured by other means not specified in this standard. If this value is used in a SET request, the agent shall respond with a badValueError. Disabled - no event log entry shall be generated or recorded due to this event. In an agent complying with NTCIP 1103 v03 or later, this event shall not be used to trigger NTCIP traps, nor to construct NTCIP trap messages. Log - an event log entry shall be generated when this event occurs. In an agent complying with NTCIP 1103 v03 and later, this may trigger an NTCIP trap (see the eventConfigID index element of trapTable). If eventConfigClass refers to an eventClassTable row having eventClassLimit = 0, the log entry's eventLogValue shall be used to construct any necessary trap messages implied by the associated trapTable rows, but the log entry shall then be discarded and not added to the eventLogTable. If the eventClassLimit is greater than zero, the log entry shall be added to the eventLogTable, subject to the constraints imposed by the associated eventConfigClass. <Superseded by> COND-TRIGGER-MIB.fdCondTriggerActionOwner, fdCondTriggerAction, fdCondTriggerActionOwner2, & fdCondTriggerAction2 (ISO 20684-3) <Informative> The replacement object points to a table that can point to multiple actions. For example, a single trigger can result in both a log entry and a notification. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}
Records for description 7NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 7

eventConfigAction · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"This value of this object indicates the action that will take place when the event described in this row of the event configuration table occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs.\"",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "This value of this object indicates the action that will take place when the event described in this row of the event configuration table occurs. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs."
    ],
    null,
    null,
    null,
    null
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1201:1996, Global Object Definitions Published December 2001 (superceded by NTCIP 1201 v02) — original PDF · Official record

    Module: GLOBAL

    See published definition above

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: The GLOBAL moduleMake/moduleVersion assignment closes its explicitly opened brace with a parenthesis. Normalize only that delimiter in the derived parsing copy; retain the original definition and unchanged numeric expression.

    Source data warning: The historical GLOBAL security grouping explicitly prints the parent global and suffix 5 but omits assignment braces. Reuse two adjacent whitespace bytes for those braces in the parsing copy; retain the original expression and qualify this syntactic interpretation. No numeric arc is invented or replaced.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names EventLogConfigTable, while its native table or entry declaration uses eventLogConfigTable. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names EventLogEntry, while its native table or entry declaration uses eventLogEntry. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names globalmoduleTable, while its native table or entry declaration uses globalModuleTable. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names moduleTableEntry, while its native table or entry declaration uses moduleEntry. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: missing or unreadable imports of devices, profiles. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1201v0110b.pdf — GLOBAL (MIB transcription)
Records for description 8NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 8

eventConfigAction · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigAction

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigAction",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "disabled",
    "(",
    "2",
    ")",
    ",",
    "log",
    "(",
    "3",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8 \"",
    "DEFVAL",
    "{",
    "disabled",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "disabled",
            2
          ],
          [
            "log",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>The value of this object indicates what action shall take place when this event occurs. other - indicates that the action is other than defined in this standard. disabled - no entry will be recorded due to this event. log - an entry will be recorded in the event log table when this event occurs. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.8"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "disabled"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.6.4.2.1.1 eventConfigID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.2 eventConfigClass00
1.3.6.1.4.1.1206.4.2.6.4.2.1.3 eventConfigMode00
1.3.6.1.4.1.1206.4.2.6.4.2.1.4 eventConfigCompareValue00
1.3.6.1.4.1.1206.4.2.6.4.2.1.5 eventConfigCompareValue200
1.3.6.1.4.1.1206.4.2.6.4.2.1.6 eventConfigCompareOID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.7 eventConfigLogOID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.9 eventConfigStatus00