Reference record for OID 1.3.6.1.4.1.6527.3.1.2.2.4.6.1.6



parent
1.3.6.1.4.1.6527.3.1.2.2.4.6.1 (tmnxSonetPathEntry)
node code
6
node name
tmnxSonetPathJ1String
dot oid
1.3.6.1.4.1.6527.3.1.2.2.4.6.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) timetra(6527) timetraProducts(3) tmnxSRMIB(1) tmnxSRObjs(2) tmnxHwObjs(2) tmnxPortObjs(4) tmnxSonetPathTable(6) tmnxSonetPathEntry(1) tmnxSonetPathJ1String(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • /iso/identified-organization/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • /iso/org/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • /iso/org/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • /iso/iso-identified-organization/dod/internet/private/enterprise/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • /iso/iso-identified-organization/dod/internet/private/enterprises/timetra/timetraProducts/tmnxSRMIB/tmnxSRObjs/tmnxHwObjs/tmnxPortObjs/tmnxSonetPathTable/tmnxSonetPathEntry/tmnxSonetPathJ1String
  • Description by circitor

    The tmnxSonetPathJ1String variable is used to configure the sonet path
    trace string to be sent in the J1 Path Overhead bytes. The bytes
    must be printable ASCII. If the string is less than 62 bytes, it
    will be padded with NULLs. For SONET framing, an additional CR (0x0D)
    / LF (0x0A) pair will be added by the driver. For SDH framing only
    16 bytes are sent in the J1 bytes. The driver will set the MSB of
    the first byte, and put the first 15 bytes of the user configured string
    as the following bytes. The driver will set the CRC-7 of the 16 bytes
    into the other 7 bits of the first byte.

    The default value is `Alcatel 7x50 SR`.
    Setting a 1-byte long string containing 0xFF will restore the default.
    Setting the string 'zeros' will send all-zeros (ASCII NULL characters
    without CR/LF or CRC-7)in the J1 bytes.

    Parsed from file TIMETRA-PORT-MIB.mib
    Module: TIMETRA-PORT-MIB

    Information by circitor

    tmnxSonetPathJ1String OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..62)) MAX-ACCESS read-create STATUS current DESCRIPTION "The tmnxSonetPathJ1String variable is used to configure the sonet path trace string to be sent in the J1 Path Overhead bytes. The bytes must be printable ASCII. If the string is less than 62 bytes, it will be padded with NULLs. For SONET framing, an additional CR (0x0D) / LF (0x0A) pair will be added by the driver. For SDH framing only 16 bytes are sent in the J1 bytes. The driver will set the MSB of the first byte, and put the first 15 bytes of the user configured string as the following bytes. The driver will set the CRC-7 of the 16 bytes into the other 7 bits of the first byte. The default value is `Alcatel 7x50 SR`. Setting a 1-byte long string containing 0xFF will restore the default. Setting the string 'zeros' will send all-zeros (ASCII NULL characters without CR/LF or CRC-7)in the J1 bytes." ::= { tmnxSonetPathEntry 6 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.6527)

    Marcelo Mourier

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.6527)

    Jason Sterne

    Brothers (16)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.1 tmnxSonetPathRowStatus 0 0 tmnxSonetPathRowStatus controls the creation and deletion of
    row entries in the tmnxSonetPathTable. The tmnxPortPortID
    for a sone…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.2 tmnxSonetPathLastChangeTime 0 0 The tmnxSonetPathLastChangeTime variable contains the sysUpTime
    value of the most recently modified writable variable in the
    tmnx…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.3 tmnxSonetPathMTU 0 0 The size of the largest packet which can be sent/received
    on the sonet path, specified in octets. For paths that
    are used for tr…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.4 tmnxSonetPathScramble 0 0 If the tmnxSonetPathScramble variable is set to 'true',
    SONET (SDH) payload scrambling is enabled on this sonet path.
    Both ends o…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.5 tmnxSonetPathC2Byte 0 0 The tmnxSonetPathC2Byte variable is used configure the value
    used in the SONET/SDH C2 header byte.

    For paths on an MDA that does…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.7 tmnxSonetPathCRC 0 0 The value of tmnxSonetPathCRC variable indicates the precision of
    the cyclic redundancy check. A value of 'crc16' is a 16-bit
    CR…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.8 tmnxSonetPathOperMTU 0 0 The negotiated size of the largest packet which can be sent on
    the sonet path, specified in octets. For sonet paths that are us…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.9 tmnxSonetPathOperMRU 0 0 The negotiated size of the largest packet that can be received
    on the sonet path, specified in octets.
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.10 tmnxSonetPathReportAlarm 0 0 The value of tmnxSonetPathReportAlarm determines when and if to
    generate tmnxEqPortSonetPathAlarm and tmnxEqPortSonetPathAlarmCl…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.11 tmnxSonetPathAcctPolicyId 0 0 The value of the accounting policy must be defined prior to associating
    the policy with the sonet path. Accounting policies can …
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.12 tmnxSonetPathCollectStats 0 0 Enable/disable the collection of accounting and statistical data
    for the network sonet path. When applying accounting policies t…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.13 tmnxSonetPathReportAlarmStatus 0 0 The bits in this object are used for indicating the alarms. The bits
    are explained as follows:
    pais(1) Indicates path alarm i…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.14 tmnxSonetPathMonC2Byte 0 0 The tmnxSonetPathC2Byte variable reports the value in the SONET/SDH
    C2 header byte.
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.15 tmnxSonetPathMonJ1String 0 0 The tmnxSonetPathJ1String variable reports the sonet path
    trace string received in the J1 Path Overhead bytes.
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.16 tmnxSonetPathType 0 0 tmnxSonetPathType specifies if the associated SONET/SDH Path
    is an asynchronous circuit, a virtual tributary group or
    a tributary…
    1.3.6.1.4.1.6527.3.1.2.2.4.6.1.17 tmnxSonetPathChildType 0 0 tmnxSonetPathChildType is used to configure the type of this path.
    Some typical default values are:
    pdhDs3 for STS-1 paths
    pdhE3 f…