OID reference

unitStartUpFlash

1.3.6.1.4.1.1206.4.2.1.3.1

Description

<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash s…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.3 (unit)
Node code
1
Node name
unitStartUpFlash
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.3.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.3.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 3 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitStartUpFlash(1)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/3/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/3/1
  • /ISO/3/6/1/4/1/1206/4/2/1/3/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitStartUpFlash
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitStartUpFlash
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory, optional

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Allowed ranges
0–255

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional
Allowed ranges
0–255

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.3.1.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

unitStartUpFlash · mandatory

unitStartUpFlash   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> Unit Start up Flash time parameter in seconds
            (0 to 255 sec). The period/state (Start-Up Flash) occurs when
            power is restored following a device defined power interruption.
            During the Start-Up Flash state, the Fault Monitor and Voltage
            Monitor outputs shall be inactive (if present) and the Channel
            Flash settings shall be overridden.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1
      <Unit> second"
      REFERENCE "NEMA TS 2 Clause 3.9.1.1"
::= { unit 1 }

unitStartUpFlash · mandatory

unitStartUpFlash OBJECT-TYPE
          SYNTAX INTEGER (0..255)
          ACCESS read-write
          STATUS mandatory
          DESCRIPTION
               "Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up
               Flash occurs when power is restored following a device defined power interruption. During
               the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if
               present)."
          REFERENCE
               "NEMA TS 2 Clause 3.9.1.1"
::= { unit 1 }

unitStartUpFlash · optional

unitStartUpFlash   OBJECT-TYPE
   SYNTAX   INTEGER (0..255)
   ACCESS   read-write
   STATUS   optional
   DESCRIPTION
      "<Definition> Unit Start up Flash time parameter in
       seconds (0 to 255 sec). The period/state (Start-Up
       Flash occurs when power is restored following a
       device defined power interruption. During the
       Start-Up Flash state, the Fault Monitor and Voltage
       Monitor outputs shall be inactive (if present).
       <DescriptiveName> NTCIP-1202::ASC.unitStartUpFlash
       <DataConceptType> Data Element
       <Unit> second"
   REFERENCE
      "NEMA TS 2 Clause 3.9.1.1"
::= { unit 1 }

unitStartUpFlash · mandatory

unitStartUpFlash   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> Unit Start up Flash time parameter in seconds
            (0 to 255 sec). The period/state (Start-Up Flash) occurs when
            power is restored following a device defined power interruption.
            During the Start-Up Flash state, the Fault Monitor and Voltage
            Monitor outputs shall be inactive (if present) and the Channel
            Flash settings shall be overridden.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1
      <Object Type> P
      <Unit> second"
      REFERENCE "NEMA TS 2 Clause 3.9.1.1"
::= { unit 1 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present).

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present). <DescriptiveName> NTCIP-1202::ASC.unitStartUpFlash <DataConceptType> Data Element <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Object Type> P <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

unitStartUpFlash · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitStartUpFlash

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitStartUpFlash",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.9.1.1\"",
    "::=",
    "{",
    "unit",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.9.1.1"
    ],
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

unitStartUpFlash · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitStartUpFlash

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitStartUpFlash",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present).\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.9.1.1\"",
    "::=",
    "{",
    "unit",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present)."
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.9.1.1"
    ],
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

unitStartUpFlash · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: unitStartUpFlash

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitStartUpFlash",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present). <DescriptiveName> NTCIP-1202::ASC.unitStartUpFlash <DataConceptType> Data Element <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.9.1.1\"",
    "::=",
    "{",
    "unit",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present). <DescriptiveName> NTCIP-1202::ASC.unitStartUpFlash <DataConceptType> Data Element <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.9.1.1"
    ],
    null,
    null,
    null
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

unitStartUpFlash · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitStartUpFlash

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitStartUpFlash",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Object Type> P <Unit> second\"",
    "REFERENCE",
    "\"NEMA TS 2 Clause 3.9.1.1\"",
    "::=",
    "{",
    "unit",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Unit Start up Flash time parameter in seconds (0 to 255 sec). The period/state (Start-Up Flash) occurs when power is restored following a device defined power interruption. During the Start-Up Flash state, the Fault Monitor and Voltage Monitor outputs shall be inactive (if present) and the Channel Flash settings shall be overridden. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.1 <Object Type> P <Unit> second"
    ],
    [
      "REFERENCE",
      "NEMA TS 2 Clause 3.9.1.1"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (26)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.3.2 unitAutoPedestrianClear00
1.3.6.1.4.1.1206.4.2.1.3.3 unitBackupTime00
1.3.6.1.4.1.1206.4.2.1.3.4 unitRedRevert00
1.3.6.1.4.1.1206.4.2.1.3.5 unitControlStatus00
1.3.6.1.4.1.1206.4.2.1.3.6 unitFlashStatus00
1.3.6.1.4.1.1206.4.2.1.3.7 unitAlarmStatus200
1.3.6.1.4.1.1206.4.2.1.3.8 unitAlarmStatus100
1.3.6.1.4.1.1206.4.2.1.3.9 shortAlarmStatus00
1.3.6.1.4.1.1206.4.2.1.3.10 unitControl00
1.3.6.1.4.1.1206.4.2.1.3.11 maxAlarmGroups00
1.3.6.1.4.1.1206.4.2.1.3.12 alarmGroupTable13
1.3.6.1.4.1.1206.4.2.1.3.13 maxSpecialFunctionOutputs00
1.3.6.1.4.1.1206.4.2.1.3.14 specialFunctionOutputTable15
1.3.6.1.4.1.1206.4.2.1.3.15 unitMCETimeout00
1.3.6.1.4.1.1206.4.2.1.3.16 unitMCEIntAdv00
1.3.6.1.4.1.1206.4.2.1.3.17 ascElevationOffset00
1.3.6.1.4.1.1206.4.2.1.3.18 unitStartUpFlashMode00
1.3.6.1.4.1.1206.4.2.1.3.19 unitUserDefinedBackupTime00
1.3.6.1.4.1.1206.4.2.1.3.20 maxUserDefinedBackupTimeContent00
1.3.6.1.4.1.1206.4.2.1.3.21 unitUserDefinedBackupTimeContentTable14
1.3.6.1.4.1.1206.4.2.1.3.22 ascClock811
1.3.6.1.4.1.1206.4.2.1.3.23 commPorts624
1.3.6.1.4.1.1206.4.2.1.3.24 maxGlobalSetIds00
1.3.6.1.4.1.1206.4.2.1.3.25 globalSetIdTable13
1.3.6.1.4.1.1206.4.2.1.3.26 unitAlarmStatus300
1.3.6.1.4.1.1206.4.2.1.3.27 unitAlarmStatus400