Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"unitControl",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"255",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition> This object is used to allow a remote entity to activate unit functions in the device ( 0 = False / Disabled, 1 = True / Enabled) as follows: Bit 7: Dimming Enable - when set to 1, causes channel dimming to operate as configured. For dimming to occur, (this control OR a dimming input) AND a 'timebaseAscAuxillaryFunction' must be True. REFERENCE NEMA TS 2 Clause 3.9.2 Bit 6: Interconnect - when set to 1, shall cause the interconnect inputs to operate at a higher priority than the timebase control (TBC On Line). REFERENCE NEMA TS 2 Clause 3.6.2.3 and 3.8.3 Bit 5: Walk Rest Modifier - when set to 1, causes non-actuated phases to remain in the timed-out Walk state (rest in Walk) in the absence of a serviceable conflicting call. REFERENCE NEMA TS 2 Clause 3.5.5.5.13 Bit 4: Call to Non-Actuated 2 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 3: Call to Non-Actuated 1 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 2: External Minimum Recall - when set to 1, causes a recurring demand on all vehicle phases for a minimum vehicle service. REFERENCE NEMA TS 2 Clause 3.5.5.5.9 Bit 1: Disable Remote Commands - when set to 1, causes a CU to ignore commands (all SET requests) from all management station except and until this bit is SET to 0 (i.e., a management station can still SET this bit to 0 to enable Remote Command). Bit 0: Reserved When a bit = 1, the device shall activate the Unit control. When a bit = 0, the device shall not activate the Unit control. A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the BACKUP timer (see unitBackupTime). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.10\"",
"::=",
"{",
"unit",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition> This object is used to allow a remote entity to activate unit functions in the device ( 0 = False / Disabled, 1 = True / Enabled) as follows: Bit 7: Dimming Enable - when set to 1, causes channel dimming to operate as configured. For dimming to occur, (this control OR a dimming input) AND a 'timebaseAscAuxillaryFunction' must be True. REFERENCE NEMA TS 2 Clause 3.9.2 Bit 6: Interconnect - when set to 1, shall cause the interconnect inputs to operate at a higher priority than the timebase control (TBC On Line). REFERENCE NEMA TS 2 Clause 3.6.2.3 and 3.8.3 Bit 5: Walk Rest Modifier - when set to 1, causes non-actuated phases to remain in the timed-out Walk state (rest in Walk) in the absence of a serviceable conflicting call. REFERENCE NEMA TS 2 Clause 3.5.5.5.13 Bit 4: Call to Non-Actuated 2 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 3: Call to Non-Actuated 1 - when set to 1, causes any phase(s) appropriately programmed in the phaseOptions object to operate in the Non-Actuated Mode. REFERENCE NEMA TS 2 Clause 3.5.5.5.8 Bit 2: External Minimum Recall - when set to 1, causes a recurring demand on all vehicle phases for a minimum vehicle service. REFERENCE NEMA TS 2 Clause 3.5.5.5.9 Bit 1: Disable Remote Commands - when set to 1, causes a CU to ignore commands (all SET requests) from all management station except and until this bit is SET to 0 (i.e., a management station can still SET this bit to 0 to enable Remote Command). Bit 0: Reserved When a bit = 1, the device shall activate the Unit control. When a bit = 0, the device shall not activate the Unit control. A SET of a 'reserved' bit to a value other than zero (0) shall return a badValue(3) error. The device shall reset this object to ZERO when in BACKUP Mode. A write to this object shall reset the BACKUP timer (see unitBackupTime). <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.10"
],
null,
null,
null,
null
]
}