Status in source: optional.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"unitAutoPedestrianClear",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disable",
"(",
"1",
")",
",",
"enable",
"(",
"2",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"optional",
"DESCRIPTION",
"\"<Definition> Unit Automatic Ped Clear parameter (1 = False/Disable 2=True/Enable). When enabled, the CU shall time the Pedestrian Clearance interval when Manual Control Enable is active and prevent the Pedestrian Clearance interval from being terminated by the Interval Advance input. <DescriptiveName> NTCIP-1202::ASC.unitAutoPedestrianClear <DataConceptType> Data Element\"",
"REFERENCE",
"\"NEMA TS 2 Clause 3.5.3.10\"",
"::=",
"{",
"unit",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disable",
1
],
[
"enable",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"optional"
],
[
"DESCRIPTION",
"<Definition> Unit Automatic Ped Clear parameter (1 = False/Disable 2=True/Enable). When enabled, the CU shall time the Pedestrian Clearance interval when Manual Control Enable is active and prevent the Pedestrian Clearance interval from being terminated by the Interval Advance input. <DescriptiveName> NTCIP-1202::ASC.unitAutoPedestrianClear <DataConceptType> Data Element"
],
[
"REFERENCE",
"NEMA TS 2 Clause 3.5.3.10"
],
null,
null,
null
]
}