OID reference

unitBackupTime

1.3.6.1.4.1.1206.4.2.1.3.3

Description

<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset it times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.3 (unit)
Node code
3
Node name
unitBackupTime
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.3.3
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.3.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 3 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitBackupTime(3)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/3/3
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/3/3
  • /ISO/3/6/1/4/1/1206/4/2/1/3/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitBackupTime
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitBackupTime
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional, mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional
Allowed ranges
0–65535

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Allowed ranges
0–65535

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.3.3.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

unitBackupTime · optional

unitBackupTime   OBJECT-TYPE
   SYNTAX   INTEGER (0..65535)
   ACCESS   read-write
   STATUS   optional
   DESCRIPTION
      "<Definition> The Backup Time in seconds (0-65535 sec).
       When any of the defined system control parameters
       is SET, the backup timer is reset. After reset it
       times the unitBackupTime interval. If the unitBackupTime
       interval expires without a SET operation to any of
       the system control parameters, then the CU shall
       revert to Backup Mode. A value of zero (0) for this
       object shall disable this feature. The system control
       parameters are:
          phaseControlGroupPhaseOmit,
          phaseControlGroupPedOmit,
          phaseControlGroupHold,
          phaseControlGroupForceOff,
          phaseControlGroupVehCall,
          phaseControlGroupPedCall,
          systemPatternControl,
          systemSyncControl,
          preemptControlState,
          ringControlGroupStopTime,
          ringControlGroupForceOff,
          ringControlGroupMax2,
          ringControlGroupMaxInhibit,
          ringControlGroupPedRecycle,
          ringControlGroupRedRest,
          ringControlGroupOmitRedClear,
          unitControl,
          specialFunctionOutputState (deprecated), and
          specialFunctionOutputControl.




                                                                                   

                                                                                       
                                                                                      

       <DescriptiveName> NTCIP-1202::ASC.unitBackupTime
       <DataConceptType> Data Element
       <Unit> second"
::= { unit 3 }

unitBackupTime · mandatory

unitBackupTime   OBJECT-TYPE
      SYNTAX INTEGER (0..65535)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> The Backup Time in seconds (0-65535 sec).
            When any of the defined system control parameters is SET, the
            backup timer is reset. After reset the CU times the
            unitBackupTime interval. If the unitBackupTime interval expires
            without a SET operation to any of the system control parameters,
            then the CU shall revert to Backup Mode. A value of zero (0) for
            this object shall disable this feature. The setting of this
            object shall be ignored if the unitUserDefinedBackupTime is set
            to a non-zero value. The system control parameters are:
                  phaseControlGroupPhaseOmit,
                  phaseControlGroupPedOmit,
                  phaseControlGroupHold,
                  phaseControlGroupForceOff,
                  phaseControlGroupVehCall,
                  phaseControlGroupPedCall,
                  systemPatternControl,



                                                                                        

                  
        

                         systemSyncControl,
                         preemptControlState,
                         ringControlGroupStopTime,
                         ringControlGroupForceOff,
                         ringControlGroupMax2,
                         ringControlGroupMaxInhibit,
                         ringControlGroupPedRecycle,
                         ringControlGroupRedRest,
                         ringControlGroupOmitRedClear,
                         unitControl,
                         specialFunctionOutputState (deprecated), and
                         specialFunctionOutputControl.

            These system control parameters are added for controllers that
            support 1202 v3 and above:
                  ringControlGroupMax3
                  vehicleDetectorControlGroupActuation
                  pedestrianDetectorControlGroupActuation
                  actionPlanControl
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3
      <Object Type> P
      <Unit> second"
::= { unit 3 }

unitBackupTime · mandatory

unitBackupTime   OBJECT-TYPE
      SYNTAX INTEGER (0..65535)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> The Backup Time in seconds (0-65535 sec).
            When any of the defined system control parameters is SET, the
            backup timer is reset. After reset the CU times the
            unitBackupTime interval. If the unitBackupTime interval expires
            without a SET operation to any of the system control parameters,
            then the CU shall revert to Backup Mode. A value of zero (0) for
            this object shall disable this feature. The setting of this
            object shall be ignored if the unitUserDefinedBackupTime is set
            to a non-zero value. The system control parameters are:
                  phaseControlGroupPhaseOmit,
                  phaseControlGroupPedOmit,
                  phaseControlGroupHold,
                  phaseControlGroupForceOff,
                  phaseControlGroupVehCall,
                  phaseControlGroupPedCall,
                  systemPatternControl,
                  systemSyncControl,
                  preemptControlState,



                                                                                        

                  
        

                         ringControlGroupStopTime,
                         ringControlGroupForceOff,
                         ringControlGroupMax2,
                         ringControlGroupMaxInhibit,
                         ringControlGroupPedRecycle,
                         ringControlGroupRedRest,
                         ringControlGroupOmitRedClear,
                         unitControl,
                         specialFunctionOutputState (deprecated), and
                         specialFunctionOutputControl.

            These system control parameters are added for controllers that
            support 1202 v3 and above:
                  ringControlGroupMax3
                  vehicleDetectorControlGroupActuation
                  pedestrianDetectorControlGroupActuation
                  actionPlanControl
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3
      <Unit> second"
::= { unit 3 }

unitBackupTime · mandatory

unitBackupTime OBJECT-TYPE
          SYNTAX INTEGER (0..65535)
          ACCESS read-write
          STATUS mandatory
          DESCRIPTION
               "The Backup Time in seconds (0-65535). When one of the defined system control
               parameters is SET, the backup timer is reset and times the unitBackupTime interval. If the
               unitBackupTime interval expires without a SET operation to one of the system control
               parameters, then the CU shall revert to Backup Mode.
               A value of zero (0) shall disable this feature.
               The system control parameters are:
               phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold,
               phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall,
               unitControl, systemPatternControl, systemSyncControl, preemptControlState,
               ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2,
               ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest,
               ringControlGroupOmitRedClear and unitControl."
::= { unit 3 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset it times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. <DescriptiveName> NTCIP-1202::ASC.unitBackupTime <DataConceptType> Data Element <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Object Type> P <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Unit> second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

The Backup Time in seconds (0-65535). When one of the defined system control parameters is SET, the backup timer is reset and times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to one of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, unitControl, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear and unitControl.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

unitBackupTime · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: unitBackupTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitBackupTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset it times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. <DescriptiveName> NTCIP-1202::ASC.unitBackupTime <DataConceptType> Data Element <Unit> second\"",
    "::=",
    "{",
    "unit",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset it times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. <DescriptiveName> NTCIP-1202::ASC.unitBackupTime <DataConceptType> Data Element <Unit> second"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

unitBackupTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitBackupTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitBackupTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Object Type> P <Unit> second\"",
    "::=",
    "{",
    "unit",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Object Type> P <Unit> second"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

unitBackupTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitBackupTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitBackupTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Unit> second\"",
    "::=",
    "{",
    "unit",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> The Backup Time in seconds (0-65535 sec). When any of the defined system control parameters is SET, the backup timer is reset. After reset the CU times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to any of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) for this object shall disable this feature. The setting of this object shall be ignored if the unitUserDefinedBackupTime is set to a non-zero value. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear, unitControl, specialFunctionOutputState (deprecated), and specialFunctionOutputControl. These system control parameters are added for controllers that support 1202 v3 and above: ringControlGroupMax3 vehicleDetectorControlGroupActuation pedestrianDetectorControlGroupActuation actionPlanControl <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.3 <Unit> second"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

unitBackupTime · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitBackupTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitBackupTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The Backup Time in seconds (0-65535). When one of the defined system control parameters is SET, the backup timer is reset and times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to one of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, unitControl, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear and unitControl.\"",
    "::=",
    "{",
    "unit",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The Backup Time in seconds (0-65535). When one of the defined system control parameters is SET, the backup timer is reset and times the unitBackupTime interval. If the unitBackupTime interval expires without a SET operation to one of the system control parameters, then the CU shall revert to Backup Mode. A value of zero (0) shall disable this feature. The system control parameters are: phaseControlGroupPhaseOmit, phaseControlGroupPedOmit, phaseControlGroupHold, phaseControlGroupForceOff, phaseControlGroupVehCall, phaseControlGroupPedCall, unitControl, systemPatternControl, systemSyncControl, preemptControlState, ringControlGroupStopTime, ringControlGroupForceOff, ringControlGroupMax2, ringControlGroupMaxInhibit, ringControlGroupPedRecycle, ringControlGroupRedRest, ringControlGroupOmitRedClear and unitControl."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (26)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.3.1 unitStartUpFlash00
1.3.6.1.4.1.1206.4.2.1.3.2 unitAutoPedestrianClear00
1.3.6.1.4.1.1206.4.2.1.3.4 unitRedRevert00
1.3.6.1.4.1.1206.4.2.1.3.5 unitControlStatus00
1.3.6.1.4.1.1206.4.2.1.3.6 unitFlashStatus00
1.3.6.1.4.1.1206.4.2.1.3.7 unitAlarmStatus200
1.3.6.1.4.1.1206.4.2.1.3.8 unitAlarmStatus100
1.3.6.1.4.1.1206.4.2.1.3.9 shortAlarmStatus00
1.3.6.1.4.1.1206.4.2.1.3.10 unitControl00
1.3.6.1.4.1.1206.4.2.1.3.11 maxAlarmGroups00
1.3.6.1.4.1.1206.4.2.1.3.12 alarmGroupTable13
1.3.6.1.4.1.1206.4.2.1.3.13 maxSpecialFunctionOutputs00
1.3.6.1.4.1.1206.4.2.1.3.14 specialFunctionOutputTable15
1.3.6.1.4.1.1206.4.2.1.3.15 unitMCETimeout00
1.3.6.1.4.1.1206.4.2.1.3.16 unitMCEIntAdv00
1.3.6.1.4.1.1206.4.2.1.3.17 ascElevationOffset00
1.3.6.1.4.1.1206.4.2.1.3.18 unitStartUpFlashMode00
1.3.6.1.4.1.1206.4.2.1.3.19 unitUserDefinedBackupTime00
1.3.6.1.4.1.1206.4.2.1.3.20 maxUserDefinedBackupTimeContent00
1.3.6.1.4.1.1206.4.2.1.3.21 unitUserDefinedBackupTimeContentTable14
1.3.6.1.4.1.1206.4.2.1.3.22 ascClock811
1.3.6.1.4.1.1206.4.2.1.3.23 commPorts624
1.3.6.1.4.1.1206.4.2.1.3.24 maxGlobalSetIds00
1.3.6.1.4.1.1206.4.2.1.3.25 globalSetIdTable13
1.3.6.1.4.1.1206.4.2.1.3.26 unitAlarmStatus300
1.3.6.1.4.1.1206.4.2.1.3.27 unitAlarmStatus400