OID reference

unitAlarmStatus1

1.3.6.1.4.1.1206.4.2.1.3.8

Description

Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7 - CoordActive - When coordination is active and not preempted or overridden. Bit 6 - Local Free - When any of the Controller Unit inputs and/or programming cause it to not respond to coordination control. Bit 5 - Local Flash - When the Controller Unit Local …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.3 (unit)
Node code
8
Node name
unitAlarmStatus1
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.3.8
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.3.8
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 3 8}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) unitAlarmStatus1(8)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/3/8
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/3/8
  • /ISO/3/6/1/4/1/1206/4/2/1/3/8
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/unitAlarmStatus1
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/unitAlarmStatus1
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory, optional

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
0–255

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
optional
Allowed ranges
0–255

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.3.8.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

unitAlarmStatus1 · mandatory

unitAlarmStatus1 OBJECT-TYPE
          SYNTAX INTEGER (0..255)
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
               "Device Alarm Mask 1 ( 0 = False, 1 = True) as follows:
                  Bit 7 - CoordActive - When coordination is active and not preempted or overridden.
                  Bit 6 - Local Free - When any of the Controller Unit inputs and/or programming cause it to
                          not respond to coordination control.
                  Bit 5 - Local Flash - When the Controller Unit Local Flash input becomes active, MMU
                          Flash input is not active, and Flash is not commanded by the system.
                  Bit 4 - MMU Flash - When the Controller Unit MMU Flash input remains active for a
                          period of time exceeding the Start-Up Flash time.
                  Bit 3 - Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode,
                          whether the result of a Cycle Fault or Free being the current normal mode, and
                          cycling diagnostics indicate that a serviceable call exists that has not been
                          serviced for two cycles.
                  Bit 2 - Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within
                          two cycles of the coordination retry.
                  Bit 1 - Coord Fault - When a Cycle Fault is in effect and the serviceable call has been
                          serviced within two cycles after the Cycle Fault.
                  Bit 0 - Cycle Fault - When the Controller Unit is operating in the coordinated mode and
                          cycling diagnostics indicate that a serviceable call exists that has not been
                          serviced for two cycles.
               Once set, a bit shall maintain it’s state as long as the condition exists."
::= { unit 8 }

unitAlarmStatus1 · optional

unitAlarmStatus1   OBJECT-TYPE
   SYNTAX   INTEGER (0..255)
   ACCESS   read-only
   STATUS   optional
   DESCRIPTION
      "<Definition> Device Alarm Mask 1 ( 0 = False,
       1 = True) as follows:
          Bit 7: CoordActive - When coordination is active
             and not preempted or overridden.
          Bit 6: Local Free - When any of the CU inputs and/or
             programming cause it not to run coordination.
          Bit 5: Local Flash - When the Controller Unit
             Local Flash input becomes active, MMU Flash
             input is not active, and Flash is not commanded
             by the system.
          Bit 4: MMU Flash - When the Controller Unit MMU
             Flash input remains active for a period of time
             exceeding the Start-Up Flash time.
          Bit 3: Cycle Fail - When a local Controller Unit
             is operating in the non-coordinated mode,
             whether the result of a Cycle Fault or Free
             being the current normal mode, and cycling
             diagnostics indicate that a serviceable call
             exists that has not been serviced for two
             cycles.
          Bit 2: Coord Fail - When a Coord Fault is in
             effect and a Cycle Fault occurs again within
             two cycles of the coordination retry.
          Bit 1: Coord Fault - When a Cycle Fault is in
             effect and the serviceable call has been
             serviced within two cycles after the Cycle
             Fault.
          Bit 0: Cycle Fault - When the Controller Unit is
             operating in the coordinated mode and cycling
             diagnostics indicate that a serviceable call
             exists that has not been serviced for two
             cycles.
       Once set, a bit shall maintain it’s state as long as
       the condition exists.
       <DescriptiveName> NTCIP-1202::ASC.unitAlarmStatus1
       <DataConceptType> Data Element"
::= { unit 8 }

unitAlarmStatus1 · mandatory

unitAlarmStatus1   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION "<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as
            follows:
            Bit 7: CoordActive - When coordination is active and not
                  preempted or overridden.
            Bit 6: Local Free - When any of the CU inputs and/or programming
                  cause it not to run coordination.
            Bit 5: Local Flash - When the Controller Unit Local Flash input
                  becomes active, MMU Flash input is not active, and Flash is
                  not commanded by the system.
            Bit 4: MMU Flash - When the Controller Unit MMU Flash input
                  remains active for a period of time exceeding the Start-Up
                  Flash time.
            Bit 3: Cycle Fail - When a local Controller Unit is operating in
                  the non-coordinated mode, whether the result of a Cycle
                  Fault or Free being the current normal mode, and cycling
                  diagnostics indicate that a serviceable call exists that
                  has not been serviced for two cycles.
            Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle
                  Fault occurs again within two cycles of the coordination
                  retry.
            Bit 1: Coord Fault - When a Cycle Fault is in effect and the
                  serviceable call has been serviced within two cycles after
                  the Cycle Fault.
            Bit 0: Cycle Fault - When the Controller Unit is operating in the
                  coordinated mode and cycling diagnostics indicate that a
                  serviceable call exists that has not been serviced for two
                  cycles.



                                                                                   

                                                                                   
                                                                                  

            Once set, a bit shall maintain its state as long as the condition
            exists.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8
      <Object Type> S"
::= { unit 8 }

unitAlarmStatus1 · mandatory

unitAlarmStatus1   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION "<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as
            follows:
            Bit 7: CoordActive - When coordination is active and not
                  preempted or overridden.
            Bit 6: Local Free - When any of the CU inputs and/or programming
                  cause it not to run coordination.
            Bit 5: Local Flash - When the Controller Unit Local Flash input
                  becomes active, MMU Flash input is not active, and Flash is
                  not commanded by the system.
            Bit 4: MMU Flash - When the Controller Unit MMU Flash input
                  remains active for a period of time exceeding the Start-Up
                  Flash time.
            Bit 3: Cycle Fail - When a local Controller Unit is operating in
                  the non-coordinated mode, whether the result of a Cycle
                  Fault or Free being the current normal mode, and cycling
                  diagnostics indicate that a serviceable call exists that
                  has not been serviced for two cycles.
            Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle
                  Fault occurs again within two cycles of the coordination
                  retry.
            Bit 1: Coord Fault - When a Cycle Fault is in effect and the
                  serviceable call has been serviced within two cycles after
                  the Cycle Fault.
            Bit 0: Cycle Fault - When the Controller Unit is operating in the
                  coordinated mode and cycling diagnostics indicate that a
                  serviceable call exists that has not been serviced for two
                  cycles.
            Once set, a bit shall maintain its state as long as the condition
            exists.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8"
::= { unit 8 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7 - CoordActive - When coordination is active and not preempted or overridden. Bit 6 - Local Free - When any of the Controller Unit inputs and/or programming cause it to not respond to coordination control. Bit 5 - Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4 - MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3 - Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2 - Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1 - Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0 - Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists. <DescriptiveName> NTCIP-1202::ASC.unitAlarmStatus1 <DataConceptType> Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8 <Object Type> S

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

unitAlarmStatus1 · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitAlarmStatus1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitAlarmStatus1",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7 - CoordActive - When coordination is active and not preempted or overridden. Bit 6 - Local Free - When any of the Controller Unit inputs and/or programming cause it to not respond to coordination control. Bit 5 - Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4 - MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3 - Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2 - Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1 - Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0 - Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists.\"",
    "::=",
    "{",
    "unit",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7 - CoordActive - When coordination is active and not preempted or overridden. Bit 6 - Local Free - When any of the Controller Unit inputs and/or programming cause it to not respond to coordination control. Bit 5 - Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4 - MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3 - Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2 - Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1 - Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0 - Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

unitAlarmStatus1 · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: unitAlarmStatus1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitAlarmStatus1",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists. <DescriptiveName> NTCIP-1202::ASC.unitAlarmStatus1 <DataConceptType> Data Element\"",
    "::=",
    "{",
    "unit",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain it’s state as long as the condition exists. <DescriptiveName> NTCIP-1202::ASC.unitAlarmStatus1 <DataConceptType> Data Element"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

unitAlarmStatus1 · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitAlarmStatus1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitAlarmStatus1",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8 <Object Type> S\"",
    "::=",
    "{",
    "unit",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8 <Object Type> S"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

unitAlarmStatus1 · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitAlarmStatus1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitAlarmStatus1",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8\"",
    "::=",
    "{",
    "unit",
    "8",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Device Alarm Mask 1 ( 0 = False, 1 = True) as follows: Bit 7: CoordActive - When coordination is active and not preempted or overridden. Bit 6: Local Free - When any of the CU inputs and/or programming cause it not to run coordination. Bit 5: Local Flash - When the Controller Unit Local Flash input becomes active, MMU Flash input is not active, and Flash is not commanded by the system. Bit 4: MMU Flash - When the Controller Unit MMU Flash input remains active for a period of time exceeding the Start-Up Flash time. Bit 3: Cycle Fail - When a local Controller Unit is operating in the non-coordinated mode, whether the result of a Cycle Fault or Free being the current normal mode, and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Bit 2: Coord Fail - When a Coord Fault is in effect and a Cycle Fault occurs again within two cycles of the coordination retry. Bit 1: Coord Fault - When a Cycle Fault is in effect and the serviceable call has been serviced within two cycles after the Cycle Fault. Bit 0: Cycle Fault - When the Controller Unit is operating in the coordinated mode and cycling diagnostics indicate that a serviceable call exists that has not been serviced for two cycles. Once set, a bit shall maintain its state as long as the condition exists. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.8"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (26)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.3.1 unitStartUpFlash00
1.3.6.1.4.1.1206.4.2.1.3.2 unitAutoPedestrianClear00
1.3.6.1.4.1.1206.4.2.1.3.3 unitBackupTime00
1.3.6.1.4.1.1206.4.2.1.3.4 unitRedRevert00
1.3.6.1.4.1.1206.4.2.1.3.5 unitControlStatus00
1.3.6.1.4.1.1206.4.2.1.3.6 unitFlashStatus00
1.3.6.1.4.1.1206.4.2.1.3.7 unitAlarmStatus200
1.3.6.1.4.1.1206.4.2.1.3.9 shortAlarmStatus00
1.3.6.1.4.1.1206.4.2.1.3.10 unitControl00
1.3.6.1.4.1.1206.4.2.1.3.11 maxAlarmGroups00
1.3.6.1.4.1.1206.4.2.1.3.12 alarmGroupTable13
1.3.6.1.4.1.1206.4.2.1.3.13 maxSpecialFunctionOutputs00
1.3.6.1.4.1.1206.4.2.1.3.14 specialFunctionOutputTable15
1.3.6.1.4.1.1206.4.2.1.3.15 unitMCETimeout00
1.3.6.1.4.1.1206.4.2.1.3.16 unitMCEIntAdv00
1.3.6.1.4.1.1206.4.2.1.3.17 ascElevationOffset00
1.3.6.1.4.1.1206.4.2.1.3.18 unitStartUpFlashMode00
1.3.6.1.4.1.1206.4.2.1.3.19 unitUserDefinedBackupTime00
1.3.6.1.4.1.1206.4.2.1.3.20 maxUserDefinedBackupTimeContent00
1.3.6.1.4.1.1206.4.2.1.3.21 unitUserDefinedBackupTimeContentTable14
1.3.6.1.4.1.1206.4.2.1.3.22 ascClock811
1.3.6.1.4.1.1206.4.2.1.3.23 commPorts624
1.3.6.1.4.1.1206.4.2.1.3.24 maxGlobalSetIds00
1.3.6.1.4.1.1206.4.2.1.3.25 globalSetIdTable13
1.3.6.1.4.1.1206.4.2.1.3.26 unitAlarmStatus300
1.3.6.1.4.1.1206.4.2.1.3.27 unitAlarmStatus400