Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"unitControlStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"other",
"(",
"1",
")",
",",
"systemControl",
"(",
"2",
")",
",",
"systemStandby",
"(",
"3",
")",
",",
"backupMode",
"(",
"4",
")",
",",
"manual",
"(",
"5",
")",
",",
"timebase",
"(",
"6",
")",
",",
"interconnect",
"(",
"7",
")",
",",
"interconnectBackup",
"(",
"8",
")",
",",
"remoteManualControl",
"(",
"9",
")",
",",
"localManualControl",
"(",
"10",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"<Definition> The Control Mode for Pattern, Flash, or Free at the device: other: control by a source other than those listed here. systemControl: control by master or central commands. systemStandby: control by local based on master or central command to use local control. backupMode: Backup Mode (see Terms). manual: control by entry other than zero in coordOperationalMode. timebase: control by the local Time Base. interconnect: control by the local Interconnect inputs. interconnectBackup: control by local TBC due to invalid Interconnect inputs or loss of sync. remoteManualControl: control by central command via remote MCE commands (See unitMCEIntAdv and unitMCETimeout). localManualControl: control via MCE and Interval Advance inputs (e.g., police panel) <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.5 <Object Type> S\"",
"::=",
"{",
"unit",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"other",
1
],
[
"systemControl",
2
],
[
"systemStandby",
3
],
[
"backupMode",
4
],
[
"manual",
5
],
[
"timebase",
6
],
[
"interconnect",
7
],
[
"interconnectBackup",
8
],
[
"remoteManualControl",
9
],
[
"localManualControl",
10
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"<Definition> The Control Mode for Pattern, Flash, or Free at the device: other: control by a source other than those listed here. systemControl: control by master or central commands. systemStandby: control by local based on master or central command to use local control. backupMode: Backup Mode (see Terms). manual: control by entry other than zero in coordOperationalMode. timebase: control by the local Time Base. interconnect: control by the local Interconnect inputs. interconnectBackup: control by local TBC due to invalid Interconnect inputs or loss of sync. remoteManualControl: control by central command via remote MCE commands (See unitMCEIntAdv and unitMCETimeout). localManualControl: control via MCE and Interval Advance inputs (e.g., police panel) <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.5 <Object Type> S"
],
null,
null,
null,
null
]
}